Abstract
Petrographic techniques have been developed to determine the nature and density of cracks that have developed after subjecting concrete to steady-state and transient heating regimes. The steady-state investigations showed that there was a good correlation between measurements of crack density and measurements of residual compressive strength. Crack density measurements taken on samples after transient heating have shown that the depth to which the compressive strength of the concrete is likely to have been significantly affected can be identified. Thus, this technique should provide very useful information for the evaluation of fire-damaged concrete.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.