Abstract

Although high intensity physical activities may represent a great proportion of the total energy expenditure in active people, only sparse studies have investigated the accuracy of wearable monitors to assess activity related energy expenditure (AEE) during high intensity exercises. Therefore, the purpose of the present study was to investigate the accuracy of the Actiheart, a light portable monitor estimating AEE based on heart rate (HR) and activity counts (ACT), during two popular activities (running and cycling) performed at high intensities. The benefit of an individual calibration of the HR-AEE relationship established during a preliminary maximal test was also evaluated. AEE was estimated in eighteen active adults (4 women and 14 men; 25 ± 4 yr) with indirect calorimetry using a respiratory gas analysis system (reference method) and the Actiheart during 5-min running and cycling at 60, 75 and 85% of maximal oxygen uptake (VO2max) previously determined during a maximal test performed on a treadmill or cycle ergometer. For the Actiheart, AEE was estimated either using the group or individual calibrated equations available in the dedicated software, and their respective HR, ACT or combined HR/ACT algorithms. When the HR algorithm was used for cycling and the HR or HR/ACT algorithms for running, AEE measured by the Actiheart increased proportionally to exercise intensity from 60 to 85% VO2max (P<0.001). Compared to indirect calorimetry, the Actiheart group calibrated equations slightly to moderately underestimated (3 to 20%) AEE for the three exercise intensities (P<0.001). Accuracy of AEE estimation was greatly improved by individual calibration of the HR-AEE relationship (underestimation below 5% and intraclass correlation coefficient [ICC]: 0.79-0.93) compared to group calibration (ICC: 0.64-0.79). The Actiheart enables to assess AEE during high intensity running and cycling when the appropriate algorithm is applied. Since an underestimation was present for group calibration, an individual and sport-specific calibration should be performed when a high accuracy is required.

Highlights

  • When the heart rate (HR) algorithm was used for cycling and the HR or HR and activity counts (ACT) (HR/ACT) algorithms for running, activity related energy expenditure (AEE) measured by the Actiheart increased proportionally to exercise intensity from 60 to 85% VO2max (P

  • Accuracy of AEE estimation was greatly improved by individual calibration of the HR-AEE relationship compared to group calibration (ICC: 0.64–0.79)

  • Quantifying precisely the activity related energy expenditure (AEE) is necessary to check the adequacy with physical activity recommendations in the general population and is crucial for athletes in whom AEE represents up to 70% of total energy expenditure [1]

Read more

Summary

Introduction

Quantifying precisely the activity related energy expenditure (AEE) is necessary to check the adequacy with physical activity recommendations in the general population and is crucial for athletes in whom AEE represents up to 70% of total energy expenditure [1]. The method is impractical in the field, and even the portable IC devices are cumbersome and restrict the mobility [2]. More applicable to field conditions, would enable determining more precisely athletes’ training volume and ensure that the dietary intake covers the actual energy expenditure. Monitors integrating accelerometers counts body movements in one or three axes and can provide valid estimation of AEE during activities mainly composed of level ambulation [3]. They have a limited ability to assess AEE during most sport activities, at higher intensities [2,4,5,6,7]

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call