Abstract
This study aimed to evaluate the dosimetric influence of 6-dimensional (6D) interfractional setup error in tongue cancer treated with intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) using daily kilovoltage cone-beam computed tomography (kV-CBCT). This retrospective study included 20 tongue cancer patients treated with IMRT (10), VMAT (10), and daily kV-CBCT image guidance. Interfraction 6D setup errors along the lateral, longitudinal, vertical, pitch, roll, and yaw axes were evaluated for 600 CBCTs. Structures in the planning CT were deformed to the CBCT using deformable registration. For each fraction, a reference CBCT structure set with no rotation error was created. The treatment plan was recalculated on the CBCTs with the rotation error (RError), translation error (TError), and translation plus rotation error (T+RError). For targets and organs at risk (OARs), the dosimetric impacts of RError, TError, and T+RError were evaluated without and with moderate correction of setup errors. The maximum dose variation ΔD (%) for D98% in clinical target volumes (CTV): CTV-60, CTV-54, planning target volumes (PTV): PTV-60, and PTV-54 was -1.2%, -1.9%, -12.0%, and -12.3%, respectively, in the T+RError without setup error correction. The maximum ΔD (%) for D98% in CTV-60, CTV-54, PTV-60, and PTV-54 was -1.0%, -1.7%, -9.2%, and -9.5%, respectively, in the T+RError with moderate setup error correction. The dosimetric impact of interfractional 6D setup errors was statistically significant (p < 0.05) for D98% in CTV-60, CTV-54, PTV-60, and PTV-54. The uncorrected interfractional 6D setup errors could significantly impact the delivered dose to targets and OARs in tongue cancer. That emphasized the importance of daily 6D setup error correction in IMRT and VMAT.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.