Abstract

This paper investigates the post-punching behaviour of reinforced concrete slab–column connections with a goal of providing adequate structural integrity reinforcement. The test results of seven interior slab–column connections are presented. A study was made of the effects of slab thickness, length of structural integrity reinforcing bars, distribution of structural integrity reinforcement in slabs with rectangular columns, and the placement of structural integrity reinforcement in slabs with drop panels. Results from this test series and other researchers were compared with predictions using the CSA A23.3-04 design equations for both punching shear and post-punching resistance. The test results demonstrated that the provision of structural integrity reinforcement in accordance with the requirements of CSA A23.3-04 resulted in significant post-punching resistance and the design equations provide a reasonable estimate of this resistance.