Abstract This paper summarizes our efforts to assess corrosion-related failure in stainless steel long-term storage containers bearing plutonium oxides and electrorefining salts. Pitting corrosion of the internal can wall is believed to occur when these salt particles deliquesce forming the electrolyte necessary for corrosion-electrochemistry. Extrapolation of pit depths from coupon studies using generalized extreme value (GEV) statistics found that the probability of a through-wall corrosion pit is finite; the maximum pit depth after 50 years would be on the order of 1.7 mm where the container wall is only 1.6 mm thick. To assess susceptibility to environmental cracking fracture toughness (J1C), experiments were used in conjunction with a J-integral diagram constructed using the GE/EPRI method for linear elastic-plastic materials. As apart of this analysis, the residual stress associated with the weld was measured using the laser contour method. The hoop stress in the weld region was found to be on the o...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.