Abstract

ObjectivesTo assess the effects of different condition-induced changes on current and novel ocular surface metrics. MethodsEighty-four healthy volunteers (22.4 ± 2.6 years) participated in this study. The ocular surface and tear film response to (1) computer use, (2) contact lens insertion and (3) tear film instillation during computer use with contact lenses were assessed. Current metrics included the ocular surface disease (OSDI) questionnaire, 5-item dry eye questionnaire (DEQ-5), bulbar redness, tear meniscus height (TMH) and non-invasive keratograph break-up time (NIKBUT). Novel metrics included the lipid layer thickness obtained from the intensity of the reflected Placido disk and the speed of tear film particles post-blink. ResultsHigher dry eye symptoms, TMH and bulbar redness, and lower values in metrics related to the intensity of the Placido disk pattern and to particle speed were found after the computer reading task (p < 0.036). When a contact lens was fitted, lower TMH, NIKBUT and particle speed metrics were obtained (p < 0.044). Mixed ANOVA revealed that artificial tears significantly ameliorated the effect of computer reading on OSDI, DEQ-5, NIKBUT, metrics related to the intensity of the Placido disk pattern and metrics related to particle speed (p < 0.033). ConclusionsComputer use and contact lens wear worsened dry eye signs and symptoms, but artificial tears ameliorated this effect. Newly developed methods can serve as a tool to detect changes in the tear film triggered by different ocular surface-disturbing conditions.