Abstract

As the variation and timely meeting thermal environment requirement of indoor air temperature has a close relationship with the thermal performance of building external wall under discontinuous radiant heating condition, one appropriate assessment method or index for assessing the building external wall thermal performance is very necessary. In order to reasonably evaluate the thermal performance of external wall under discontinuous radiant heating condition and build the direct connections and interactions among the indoor air temperature, external wall inner surface temperature and outdoor air temperature, the first and second impact factors of temperature deviation were established, based on one mathematical model of room heat transfer. For one experimental room and four types of external walls under discontinuous radiant heating condition, both the influence of the external wall inner surface temperature deviation on the indoor air temperature and that of the outdoor air temperature deviation on the external wall inner surface temperature were determined effectively with the first and second impact factors of temperature deviation. In addition, favourable performance for the self-insulation and inner insulation walls were found, due to their superiority in effectively and timely improving the indoor thermal environment under discontinuous radiant heating condition.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call