Abstract
BackgroundThe assessment of interatrial septum (IAS) requires a standardized, systematic approach, including two-dimensional transthoracic echocardiography (2D TTE), 2D transesophageal echocardiography (2D TEE), and three-dimensional (3D) TEE. Although 2D TEE has been widely used for the preoperative assessment of atrial septal defect (ASD), its ability to provide reliable information is often limited due to the structural characteristics of IAS. The introduction of 3D TEE provides a unique “en face” view of IAS, which allows the visualization and accurate measurements of diameters, area, and rims of ASD. Hence, appropriate ASD imaging information is particularly important in successful transcatheter closure.MethodsIn this retrospective study, 2D TTE/TEE, and 3D TEE were performed before ASD closure, with 2D minimal and maximal diameters, areas, and residual rims being recorded. Adequate 3D TEE imaging data sets were collected and then analyzed. ASD related parameters were compared using different echocardiography. Patients who underwent ASD closure completed a clinical follow-up.ResultsThe mean defect maximal diameter and aperture area by 3D TEE was significantly larger than that of the corresponding 2D TEE (P<0.05). There was no statistical difference in the minimal and maximal diameter or area by TEE for circular-shaped ASDs. For oval ASDs, mean minimal diameter on 2D TEE was larger than that on 3D TEE. The mean maximal diameter measured using 2D TEE was smaller than the 3D TEE measurement (16.0±7.1 vs. 19.8±8.6; P<0.05). For complex-shaped defects, there were statistical differences in minimal and maximal diameter between TEEs. Furthermore, 2D and 3D TEE had a longer superior vena cava (SVC) residual rim than did 2D TTE (P<0.05). The 3D TEE residual rims of the inferior vena cava (IVC) was significantly larger than the corresponding 2D TEE. There was a very strong correlation between the residual rim measurements using 3D and 2D TEE. However, the limits of agreement between 2D and real-time 3D TEE measurements were more apparent in the IVC rim group than in the other groups.ConclusionsOur study confirms the value of 3D TEE in assessing ASD shape and size reported by previous studies, and is also the first to accurately and systematically characterize ASD residual rim in complex ASDs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.