Abstract

Simple SummaryProstate-specific antigen is a biomarker for prostate cancer. If the level of prostate-specific antigen is high, a prostate biopsy is needed to diagnose prostate cancer. However, the definite level of prostate-specific antigen that requires prostate biopsy has not been established. Currently, there are many kinds of assay modalities that have been used for prostate-specific antigen testing. This study was conducted under the hypothesis that there will be differences between different assay modalities; therefore, there is no definite prostate-specific antigen level for prostate biopsy. In our study, the level of prostate-specific antigens was measured in one blood sample per patient, with two different assay modalities in 4810 patients. As a result, we confirmed that the overall agreement between the two modalities is excellent, but the agreement is slightly different in some ranges that may give clinical significance. Accordingly, the conformity between each assay modality should be secured in the future, and the threshold for the level of prostate-specific antigens for biopsy by each assay modality should be independently determined.There is controversy over the usefulness of prostate-specific antigen (PSA) as a prostate cancer (PCa) biomarker. This controversy arises when there are differences in the results of PSA assay modalities. In this study, which aimed to evaluate a proper validation between the two PSA assay modalities, the agreement between the results of the two modalities was analyzed. PSA examinations were conducted using two PSA assay modalities in 4810 patients. The intra-class correlation coefficient (ICC) and weighted kappa analysis were used to evaluate the agreement between the two assay modalities. A linear regression was performed to evaluate the association between the two assay modalities. According to ICC values (ICC: 0.999, p < 0.001) and weighted kappa analysis values (kappa: 0.951, alpha’s standard error (ASE): 0.001, p < 0.0001), the agreement between the assay modalities was rated as excellent. However, the strength of agreement was poor in the following PSA sub-groups: 0.05–0.1 ng/mL (ICC: 0.281, p = 0.0860); 0.15–0.2 ng/mL (ICC: 0.288, p = 0.0036); 1.5–2.0 ng/mL (ICC: 0.360, p = 0.0860); and 2.0–2.5 ng/mL (ICC: 0.303, p = 0.0868). In linear regression analysis, when modality B PSA yielded a value of 0.2 ng/mL, the expected value for modality A was 0.258 ng/mL (95% CI: 0.255–0.260), and when modality B PSA yielded a value of 4 ng/mL, the expected value for modality A was 3.192 ng/mL (95% CI: 3.150–3.235). The difference in the PSA values between the two PSA assay modalities is confirmed, and this difference may be clinically meaningful.

Highlights

  • Prostate-specific antigen (PSA) was first introduced by Wang et al in 1979 [1]

  • In 1991, Catalona et al reported that PSA was superior to prostate cancer (PCa) detection compared to digital rectal examination and proposed it as a useful tool for screening PCa [3]

  • Kim et al reported that there was no significant difference in the detection rate of PCa when they compared the group of PSA levels with 2.5–4.0 ng/mL and those with 4.0–10.0 ng/mL [8]

Read more

Summary

Introduction

PSA is a glycoprotein produced by the epithelial component of the prostate gland. Many studies have suggested that the PSA cut-off value for PCa set as 4 ng/mL is too high. Kim et al reported that there was no significant difference in the detection rate of PCa when they compared the group of PSA levels with 2.5–4.0 ng/mL and those with 4.0–10.0 ng/mL [8]. There is still no definite PSA cut-off value for prostate biopsy for the detection of PCa. PSA is used in PCa screening and in the monitoring of disease progression in an untreated group and in the evaluation of treatment response [2,9,10,11,12]. PSA in post-treatment follow-up has clinical significance at a very low level, and the accuracy and reliability of the PSA test are required

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.