Abstract

From October 2004 to September 2005, Radon222 activity in high-risk indoor spaces used by employees and students at the University of Genoa was measured with CR-39 nuclear track detectors. The mean concentration in winter (78.9 Bq/m3 +/- 74.92 S.D.) was low in relation to the microenvironment considered. When data were broken down by type and location of the spaces, no significant differences were found, despite the fact that the Genoa conurbation lies on soil of variable geological composition. The dose absorbed by employees was 0.42 mSv/year, with a relative risk of 4.2/1000 cases of Radon-related lung cancer. The dose absorbed by students was 0.28 mSv/year, with a relative risk of 2.5/1000 cases of Radon-related lung cancer. The level of radon activity detected never exceeded the limit of 500 Bq/m3 established by Italian law. Nevertheless, the value of the compound uncertainty index suggested that the real level of Radon contamination could have exceeded 400 Bq/m3 in selected spaces, a value requiring annual concentration tests.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.