Abstract

The mean frequency of the power spectrum (MNF) is commonly used to describe the frequency content of an electromyographic (EMG) signal. The objective of this study is to determine the minimum/desirable signal to noise ratio (SNR) value to achieve a reliable measurement of the MNF in superficial EMG (sEMG) signals of lower limbs during gait. To this end, measurements of MNF and SNR were taken in nine muscles of 21 subjects, and recorded signals were contaminated with different noise levels. The minimum threshold of a desirable SNR was determined using the K-means algorithm. A lower bound of 5.51 dB was determined as the SNR value for sEMG acquisition, while 12.28 dB is the desirable SNR value for recording sEMG signals. The methodology presented throughout this paper helps in the determination of the minimum SNR value necessary to validate the sEMG acquisition process that can be used, for example, as a control signal for identifying motion intention in the development of control systems devoted for a lower limb exoskeleton.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.