Abstract

Orthopaedic implants have been the subject of intense research in recent years, with academics, clinicians and industrialists seeking to broaden our understanding of their function and potential consequences within the human body. Current research is focussed on ways to improve the integration of an orthopaedic device within the body, whether it be to encourage better osseointegration, combat possible infection or stem the foreign body response. A key emerging strategy is the controlled delivery of therapeutics from the device, which may take the form of, for example, antibiotics, analgesics, anti-inflammatories or growth factors. However, the optimal device design that gives rise to the desired controlled release has yet to be defined. There are many examples in the literature of experimental approaches which attempt to tackle this issue. However, the necessity of having to conduct multiple experiments to test different scenarios is a major drawback of this approach. So enter stage left: mathematical modelling. Using a mathematical modelling approach can provide much more than experiments in isolation. For instance, a mathematical model can help identify key drug release mechanisms and uncover the rate limiting processes; allow for the estimation of values of the parameters controlling the system; quantify the effect of the interaction with the biological environment; and aid with the design of optimisation strategies for controlled drug release. In this paper we review current experimental approaches and some relevant mathematical models and suggest the future direction of such approaches in this field.

Highlights

  • There are a plethora of experimental approaches in the literature focussed on examining the potential of drug release from Orthopaedic implants (OIs); to the best of our knowledge, there are no mathematical models of drug release specific to OIs

  • It is worth considering a coupled model as it is important to understand the release of drugs from OIs, it would be wise to have an understanding of the biological environment, including drug/tissue interactions, as this may affect drug release. With these points in mind, we suggest that experiments should be conducted in tandem with mathematical modelling

  • In this review we have highlighted some of the key issues from the use of OIs and have provided examples of experimental approaches to aid in the understanding of drug release from OIs via prototype devices, coatings and materials

Read more

Summary

Introduction

Orthopaedic implants (OIs) have proven to be a very successful addition to the field of medicine. Examples of these devices include plates, screws and intramedullary rods to stabilise fractures, prosthetic hip and knee joints, and replacement intervertebral disks. OIs were designed to serve one of two purposes: either to act as a fixation device to provide mechanical stabilisation or to replace a joint or bone, such as a hip replacement. The former is achieved by reducing the stress and strain on the affected bone, essentially sharing the load. OIs allow for restored mobility, reduced pain and improving the overall quality of life for millions of recipients the world over [1]

Objectives
Methods
Findings
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.