Abstract
This paper examines wake effects for floating wind farms with shared anchors. Three 20-turbine farms are examined: a grid-formation baseline with no shared anchors, a farm based on 3-line anchors, and a farm based on 6-line anchors, governed by a wind turbine spacing of 8 rotor diameters. The IEA 15 MW reference turbine on the UMaine semisubmersible platform was used with a taut mooring system in deep- water depths representative of U.S. west coast lease areas. A steady-state wake model showed that, when evaluating a sweep of wind headings, the baseline design had the lowest wake losses, with a value of 11.7 %, followed by the 6-line at 12.9% and the 3-line at 13.8%. Dynamic simulations were run in FAST.Farm to analyse the effects of wakes on mean anchor loads for wind headings that showed significant wake losses. The baseline farm showed the largest anchor load reductions due to wake effects (up to 16%), followed by the 3-line farm (up to 8%), and the 6-line farm, which showed relatively consistent load magnitudes on the 6-line anchors across all headings.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.