Abstract

Abstract Funding Acknowledgements Type of funding sources: None. Background Among patients undergoing transvenous lead extraction (TLE), differences in complication rate and 1-year mortality has been explored in patients with cardiac resynchronisation therapy (CRT) devices. Longer term outcomes and the influence of timing of reimplantation of device, with respect to rehospitalisation and longer-term mortality is poorly understood. Purpose The purpose of this study was to evaluate whether early reimplantation following TLE in patients with CRT devices influenced survival and rehospitalisation. Methods Clinical data from consecutive patients undergoing TLE in the reference centre between the years 2000 to 2019 were prospectively collected. Patients surviving to discharge who were re-implanted with the same device were included. The cohort was split depending on whether or not they had a CRT device at time of explant. The association between TLE in CRT patients and all-cause mortality and re-hospitalisation was assessed by Kaplan Meier estimates in a 1:1 propensity-score matched cohort, with a calliper of 0.10. Early reimplantation was defined as reimplantation within 7 days of TLE, and late reimplantation as reimplantation after greater than 7 days of TLE. Results Of 1005 patients included in the analysis, 285 (25%) had a CRT device. After matching, 192 CRT patients were compared with 192 non-CRT patients. Propensity scores were calculated using 39 baseline characteristics, including age, gender, co-morbidities, TLE indication, left ventricular ejection fraction, baseline creatinine and technical extraction data. Mean follow up was 53.5 ± 38.3 months, mean age at explant was 67.7 ± 12.1 years, 83.3% were male and 54.4% had an infective indication for TLE. In the matched cohort, there was no significant difference between the CRT and non-CRT group with respect to long-term mortality (hazard ratio [HR] = 1.01, 95% confidence interval [CI] [0.74-1.39], p = 0.093) or rehospitalisation (HR = 1.2 [0.87-1.66], p = 0.265). A similar proportion of patients were reimplanted within 7 days in the CRT and non-CRT groups (59.4% vs 61.5%, p = 0.754). In the matched non-CRT group, late reimplantation was associated with similar mortality to early reimplantation (HR = 1.33 [0.86-2.05], p = 0.208) and rehospitalisation (HR = 0.88 [0.53-1.45], p = 0.603). In the matched CRT group, late reimplantation was associated with higher mortality (HR = 1.64 [1.04-2.57], p = 0.032) and rehospitalisation (HR = 1.57 [1.00-2.46], p = 0.049] (see figure). Conclusion In this closely matched population, TLE in CRT patients resulted in similar long-term outcomes compared with non-CRT patients. Early reimplantation post CRT explant was associated with reduced long-term mortality and rehospitalisation. This suggests a longer duration without biventricular pacing post TLE may induce negative reverse-remodelling and should be avoided in a CRT population. Abstract Figure. Kaplan-Meier survival curves

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call