Abstract

A critical problem derived from airport operations is the environmental impact of runoff water. Airport runoff includes a complex mixture of pollutants, e.g., from deicing agents, that may affect negatively natural water bodies. This study assesses the spatial and temporal aquatic ecotoxicity of runoff water and possible aeroplane drift in a German airport. Over winter 2012–2013, from November to May, water samples were collected within the airport and surrounding area. These samples were analyzed using traditional physicochemical analysis and biotests with two aquatic organisms from different trophic levels, Lemna gibba and Aliivibrio fischeri. Overall, the samples examined in this study were relatively non-toxic to the tested organisms. The physicochemical parameters were mainly influenced by the sampling period being higher in colder months. In contrast, the ecotoxicity was influenced by the sampling site. For sites within the airport, a high correlation between the physicochemical parameters (EC and TOC) and toxicity in L. gibba was found. These correlations were not evident in samples taken outside the airport or when A. fischeri was used as a bioindicator. However, a pronounced seasonality has been observed, linked to the coldest months with average inhibition values of 50% in L. gibba and 25% in A. fischeri, particularly in January. Both biotests yielded differing results; therefore, more biotests should be included. However, L. gibba showed a good response with this type of water samples to be included in future studies together with detailed chemical analysis. The present study provides data to assess the potential ecotoxicological effects of airport runoff affected by winter operations.

Highlights

  • Air traveling is regarded as the most convenient method of traveling long distances

  • The present study focuses on (1) temporal and spatial assessment of airport runoff water using bioassays and physicochemical analysis, and (2) on whether relationships exist between the water chemistry and the ecotoxicity data

  • Results on the toxicity criteria, half-maximal effective concentration (EC50), or 10% effective concentration (EC10) obtained from both bioassays are summarized in Appendix B (Tables A4A5)

Read more

Summary

Introduction

The original online version of this article was revised due to a retrospective Open Access order. Airplanes are usually sprayed with a mixture consisting of a chemical deicing fluid mainly based on glycol having other additives consisting of corrosion inhibitors, thickeners, surfactants, antifoaming agents, and dyes (Johnson, 2012). The formulation of these additives is a proprietary mixture differing among manufacturers

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call