Abstract

The mixing problem of electroencephalography (EEG) in the presence of common source could affect directed functional connectivity measures, resulting in an incorrect directionality of information flow between two signals. Here we introduce directed Weighted Phase Lag Index (dWPLI), a signed version of Weighted Phase Lag Index (WPLI) and compare this measure to Granger Causality (GC), Symbolic Transfer Entropy (STE), Phase Slope Index (PSI), and directed Phase Lag Index (dPLI) under common source effects. Robustness of the measures was tested in both analytic and simulating ways. For the simulated time series, signals were generated from unidirectionally coupled autoregressive model and linearly mixed to achieve volume conduction and common noise effects. As expected from the analytic calculation, dPLI and dWPLI were unaffected by the volume conduction while PSI, GC and STE were largely affected. (Figure ​(Figure1A).1A). The mean percentages of false identification were 14.00±7.66, 22.35±4.78, 27.38±7.04, 1.99±1.36, and 1.63±1.28, for the GC, STE, PSI, dPLI, and dWPLI, respectively. Figure 1 A. Directionalities of five directed connectivity measures under the volume conduction effect. Positive Directionality Index (DI) implies correct directionality of information flow. As M (mixing ratio) increases, the DIs of GC, STE and PSI decrease. However, ... For the common noise case, only dPLI and dWPLI had their signs preserved. (Figure ​(Figure1B).1B). The mean percentages of false identification were 30.14 ± 16.86, 49.74 ± 16.63, 34.72 ±10.23, 2.68 ± 1.90, and 2.34 ± 1.55. Furthermore, the dWPLI outperformed dPLI for the common noise case (p <0.01, Wilcoxon signed-rank test) which was also predicted from analytic calculation. Present study shows the common source effects might lead to biased results with incorrect directionality of information flow. Among the five directed functional connectivity measures, dWPLI is much less affected by common source effects.

Highlights

  • The mixing problem of electroencephalography (EEG) in the presence of common source could affect directed functional connectivity measures, resulting in an incorrect directionality of information flow between two signals

  • For the simulated time series, signals were generated from unidirectionally coupled autoregressive model and linearly mixed to achieve volume conduction and common noise effects

  • As expected from the analytic calculation, directed Phase Lag Index (dPLI) and directed Weighted Phase Lag Index (dWPLI) were unaffected by the volume conduction while Phase Slope Index (PSI), Granger Causality (GC) and Symbolic Transfer Entropy (STE) were largely affected. (Figure 1A)

Read more

Summary

Introduction

The mixing problem of electroencephalography (EEG) in the presence of common source could affect directed functional connectivity measures, resulting in an incorrect directionality of information flow between two signals. Assessing performance of directed functional connectivity measures in the presence of common source From 24th Annual Computational Neuroscience Meeting: CNS*2015 Prague, Czech Republic.

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.