Abstract
To determine the accuracy of magnetic resonance imaging-proton density fat fraction (MRI-PDFF) measurements for detecting liver fat content in potential living liver donors and to compare these results using liver biopsy findings. A total of 139 living liver donors (men/women: 83/56) who underwent MRI between January 2017 and September 2021 were included in this analysis retrospectively. The PDFFs were measured using both MR spectroscopy (MRS) and chemical shift-based MRI (CS-MRI) for each donor in a blinded manner. Significant positive correlations were found between liver biopsy and MRS-PDFF and CS-MRI PDFF in terms of hepatic steatosis detection [r = 0.701, 95% confidence interval (CI): 0.604–0.798, r = 0.654, 95% CI: 0.544–0.765, P < 0.001, respectively). A weak level correlation was observed between liver biopsy, MRI methods, and vibration-controlled transient elastography attenuation parameters in 42 available donors. Based on receiver operating characteristic (ROC) analysis, MRS-PDFF and CS-MRI PDFF significantly distinguished >5% of histopathologically detected hepatic steatosis with an area under the ROC curve (AUC) of 0.837 ± 0.036 (P < 0.001, 95% CI: 0.766–0.907) and 0.810 ± 0.036 (P < 0.001, 95% CI: 0.739–0.881), respectively. The negative predictive values (NPVs) of MRS-PDFF and CS-MRI PDFF were 88.3% and 81.3%, respectively. In terms of distinguishing between clinically significant hepatic steatosis (≥10% on histopathology), the AUC of MRS-PDFF and CS-MRI were 0.871 ± 0.034 (P < 0.001 95% CI: 0.804–0.937) and 0.855 ± 0.036 (P < 0.001, 95% CI: 0.784–0.925), respectively. The NPVs of MRS-PDFF and CS-MRI were 99% and 92%, respectively. The methods of MRS-PDFF and CS-MRI PDFF provide a non-invasive and accurate approach for assessing hepatic steatosis in potential living liver donor candidates. These MRI PDFF techniques present a promising clinical advantage in the preoperative evaluation of living liver donors by eliminating the requirement for invasive procedures like liver biopsy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Diagnostic and interventional radiology (Ankara, Turkey)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.