Abstract

BackgroundThe purpose of the study was to evaluate the feasibility of deformable image registration (DIR) in assessing cumulative dose distributions of the combination of external beam radiotherapy (EBRT) and fractionated intracavitary brachytherapy (ICBT) for cervical cancer.Materials and methodsThree-dimensional image data sets of five consecutive patients were used. The treatment plan consisted of whole pelvic EBRT (total dose: 45 Gy in 25 fractions) combined with computed tomography (CT)-based high-dose rate ICBT (≥24 Gy in 4 fractions to the high risk clinical target volume (HR-CTV)). Organs at risk and HR-CTV were contoured on each CT images and dose-volume parameters were acquired. Pre-imaging preparations were performed prior to each ICBT to minimize the uncertainty of the organ position. Physical doses of each treatment were converted to biologically equivalent doses in 2 Gy daily fractions by the linear quadratic model. Three-dimensional dose distributions of each treatment were accumulated on CT images of the first ICBT using DIR with commercially available image registration software (MIM Maestro®). To compare with DIR, 3D dose distributions were fused by rigid registration based on bony structure matching. To evaluate the accuracy of DIR, the Dice similarity coefficient (DSC) was measured between deformed contours and initial contours.ResultsThe cumulative dose distributions were successfully illustrated on the CT images using DIR. Mean DSCs of the HR-CTV, rectum, and bladder were 0.46, 0.62 and 0.69, respectively, with rigid registration; and 0.78, 0.76, and 0.87, respectively, with DIR (p <0.05). The mean DSCs derived from our DIR procedure were comparable to those of previous reports describing the quality of DIR algorithms in the pelvic region. DVH parameters derived from the 2 methods showed no significant difference.ConclusionsOur results suggest that DIR-based dose accumulation may be acceptable for assessing cumulative dose distributions to assess doses to the tumor and organs at risk in combined radiotherapy for cervical cancer under pre-imaging preparations.

Highlights

  • The purpose of the study was to evaluate the feasibility of deformable image registration (DIR) in assessing cumulative dose distributions of the combination of external beam radiotherapy (EBRT) and fractionated intracavitary brachytherapy (ICBT) for cervical cancer

  • The cumulative dose distributions were successfully illustrated on the computed tomography (CT) images using DIR

  • The mean Dice similarity coefficient (DSC) derived from our DIR procedure were comparable to those of previous reports describing the quality of DIR algorithms in the pelvic region

Read more

Summary

Introduction

The purpose of the study was to evaluate the feasibility of deformable image registration (DIR) in assessing cumulative dose distributions of the combination of external beam radiotherapy (EBRT) and fractionated intracavitary brachytherapy (ICBT) for cervical cancer. “Rectal and bladder points” have been used as reference points for the assessment of rectal and bladder doses, according to Report 38 of the International Commission on Radiation Units and Measurements [2]. These points are hypothetical, and do not always represent the actual tumor volume or the exact locations of the highest doses in the rectum and bladder [3,4]. Several studies have demonstrated that 3D dosevolume parameters of the target volume and organs at risk (OARs) are useful for predicting treatment response and toxicity development [8,9,10,11,12]

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call