AbstractPlanar laser‐induced fluorescence (PLIF) and electrical resistance tomography (ERT) were applied simultaneously to monitor the mixing performance of a KM static mixer for the blending of non‐Newtonian fluids of dissimilar rheologies in the laminar regime. The areal distribution method was used to obtain quantitative information from the ERT tomograms and the PLIF images. Comparison of the ERT and PLIF results demonstrates the ability of ERT to detect the mixing performance in cases of poor mixing within the resolution of the measurement, though the accuracy decreases as the condition of perfect mixing is approached. Thus, ERT has the potential to detect poor mixing within the confines of its resolution limit and the required conductivity contrast, providing potential rapid at‐line measurement for industrial practitioners.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.