Abstract

Radial head replacement should be a routine treatment in cases of non-reconstructable radial head fractures. With the growing number of radial head arthroplasties, we are going to see more complications related to this procedure. We describe a case of aseptic destruction of the elbow joint, probably related to the release of polyethylene particles from the prosthetic head. Removal of the implant and extensive synovectomy was performed, leading to an excellent clinical outcome with reduction of pain and increase in the range of motion. The clinical improvement was not accompanied by radiographic change.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.