Abstract

The ASCOPE Correlation Programme for octane number measurement obtains precision octane number data for gasoline using the CFR engine and the normally used method: ASTM 2699 and IP 237. The test results of the various participating laboratories are subjected to statistical analysis to determine average values, variance, standard deviation and to reject the outliers values. The Grubbs T-test is used for the statistical rejection of outliers. This method is used by both NEG and ASCOPE in their laboratory test correlation programme. The Grubb T-test appears to be quite satisfactory for ASCOPE purposes. The implementation of the Grubbs T-test assures inter-laboratory consistency and this in turn will give the buyer or seller of the gasoline confidence in the quality of the fuel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.