Abstract

The use of an artificial intelligence (AI)-based diagnostic system can significantly aid in analyzing the histogram of pulmonary nodules. The aim of our study was to evaluate the value of computed tomography (CT) histogram indicators analyzed by AI in predicting the tumor invasiveness of ground-glass nodules (GGNs) and to determine the added value of contrast-enhanced CT (CECT) compared with nonenhanced CT (NECT) in this prediction. This study enrolled patients with persistent GGNs who underwent preoperative NECT and CECT scanning. AI-based histogram analysis was performed for pathologically confirmed GGNs, which was followed by screening invasiveness-related factors via univariable analysis. Multivariable logistic models were developed based on candidate CT histogram indicators measured on either NECT or CECT. Receiver operating characteristic (ROC) curve and precision-recall (PR) curve were used to evaluate the models' performance. A total of 116 patients comprising 121 GGNs were included and divided into the precancerous lesion and adenocarcinoma groups based on invasiveness. In the AI-based histogram analysis, the mean CT value [NECT: odds ratio (OR) =1.009; 95% confidence interval (CI): 1.004-1.013; P<0.001] and solid component volume (NECT: OR =1.005; 95% CI: 1.000-1.010; P=0.032) were associated with the adenocarcinoma and used for multivariable logistic modeling. The area under ROC curve (AUC) and PR curve (AUPR) were not significantly different between the NECT model (AUC =0.765, 95% CI: 0.679-0.837; AUPR =0.907, 95% CI: 0.825-0.953) and the optimal CECT model (delayed phase: AUC =0.772, 95% CI: 0.687-0.843; AUPR =0.895, 95% CI: 0.812-0.944). No significantly different metrics were observed between the NECT and CECT models (precision: 0.707 vs. 0.742; P=0.616). The AI diagnostic system can help in the diagnosis of GGNs. The system displayed decent performance in GGN detection and alert to malignancy. Mean CT value and solid component volume were independent predictors of tumor invasiveness. CECT provided no additional improvement in diagnostic performance as compared with NECT.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.