Abstract
Artificial ground freezing method was employed in the rehabilitation project of a subsea tunnel. To ensure safety of the subsea rehabilitation work, special design and research were conducted considering the unfavorable influence of the salt in seawater had on freezing effect, such as thickness thinning and strength loss of the frozen wall. A shell-shaped frozen soil wall was designed to cut off the leakage channel into the shield. Double rows of vertical freezing pipes with limited-depth freezing were settled in front of the cutter head, and auxiliary freezing pipes were settled at the sides of the shield to achieve the design goal. Results of analyzing monitoring data on frozen soil temperature showed that the design was reasonable for shield rehabilitation in subsea stratum.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.