Abstract

Traditional arthroscopic examination is subjective and poorly reproducible. Recently, we introduced an arthroscopic ultrasound method for quantitative diagnostics of cartilage lesions. Here we describe our investigation of the feasibility of ultrasound arthroscopy for simultaneous measurements of articular cartilage and subchondral bone. Human osteochondral samples (n = 13) were imaged using a clinical 9-MHz ultrasound system. Ultrasound reflection coefficients (R, IRC), the ultrasound roughness index (URI) and the apparent integrated backscattering coefficient (AIB) were determined for both tissues. Mechanical testing, histologic analyses and micro-scale computed tomography imaging were the reference methods. Ultrasound arthroscopies were conducted on two patients. The ultrasound reflection coefficient correlated with the Mankin score and Young's modulus of cartilage (|r| > 0.56, p < 0.05). Ultrasound parameters (R, IRC, AIB) for subchondral bone correlated with the bone surface/volume ratio (|r| > 0.70, p < 0.05) and trabecular thickness (|r| > 0.59, p < 0.05). Furthermore, R and subchondral bone mineral density were significantly correlated (|r| > 0.65, p < 0.05). Arthroscopic ultrasound examination provided diagnostically valuable information on cartilage and subchondral bone in vivo.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call