Abstract

To evaluate mid-term clinical outcomes, complications, bone-block healing, and positioning using suture-button fixation for an arthroscopic Latarjet procedure. Patients with traumatic recurrent anterior instability and glenoid bone loss underwent guided arthroscopic Latarjet with suture-button fixation. We included patients with anterior shoulder instability, glenoid bone loss >20%, and radiographic and clinical follow-up minimum of 24months. Patients with glenoid bone loss <20% or those that refused computed tomography imaging were excluded. Bone-block fixation was accomplished with 2 cortical buttons connected with a looped suture (4 strands). The looped suture was tied posteriorly with a sliding-locking knot. After transfer of the bone block on the anterior neck of the scapula, compression (100N) was obtained with the help of a tensioning device. Clinical assessment was performed at 2 weeks, 3 months, 6 months, and then yearly with computed tomography completed at 2 weeks and 6 months to confirm bony union. A consecutive series of 136 patients underwent arthroscopic Latarjet with 121 patients (89%; mean age 27 years) available at final follow-up (mean follow-up, 26months; range, 24-47months). No neurologic complications or hardware failures were observed; no patients had secondary surgery for implant removal. The transferred coracoid process healed to the scapular neck in 95% of the cases (115/121). The bone block did not heal in 4 patients; it was fractured in 1 and lysed in another. Smoking was a risk factor associated with nonunion (P < .001). The coracoid graft was positioned flush to the glenoid face in 95% (115/121) and below the equator in 92.5% (112/121). At final follow-up, 93% had returned to sports, whereas 4 patients (3%) had a recurrence of shoulder instability. The subjective shoulder value for sports was 94 ± 3.7%. Mean Rowe and Walch-Duplay scores were 90 (range, 40-100) and 91 (range, 55-100), respectively. Suture-button fixation is an alternative to screw fixation for the Latarjet procedure, obtaining predictable healing with excellent graft positioning, and avoiding hardware-related complications. There was no need for hardware removal after suture-button fixation. The systematic identification of the axillary and musculocutaneous nerves reduced risk of neurologic injury. A low instability recurrence rate and excellent return to pre-injury activity level was found. Suture-button fixation is simple, safe, and may be used for both open and arthroscopic Latarjet procedure. Level IV, therapeutic case series.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call