Abstract

This study compares the strength and rigidity of four methods of internal fixation for arthrodesis of the first metatarsophalangeal joint. Ten matched pairs of cadaveric first rays were harvested and arthrodesis performed by one of four techniques: (1) planar excision of joint surfaces and fixation with crossed Kirschner wires, (2) planar excision of joint surfaces and internal fixation with a dorsal plate and screws, (3) planar excision of joint surfaces and internal fixation with an interfragmentary screw, or (4) excision of the joint surfaces using powered conical reamers and fixation with an interfragmentary lag screw. Biomechanical testing with a Bionix 858 materials testing machine was carried out, applying a plantar force utilizing principles of cantilever loading. Force applied and displacement of the arthrodesis were recorded. Of the four methods tested, bony preparation with power conical reamers and supplementary interfragmentary screw fixation was the most stable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.