Abstract
In a patient with end stage ischemic heart failure scheduled for implantation of an axial flow pump small arteriolar flow pattern was recorded using a novel intravital microscope. Preoperative arteriolar blood flow velocity was highly pulsatile, ranging from about 7 to 16 mm per second in a 12.8 microm diameter arteriole. After implantation of the pump, this pulsatility was abrogated and arteriolar blood flow velocity changed instantaneously with changes in pump speed (eg, 2 mm/s at 5,000 rpm vs 3.5 mm/s at 8,000 rpm in an 8.9 microm diameter arteriole). This lack of flow velocity oscillations may have profound long-term effects on shear stress regulated arteriolar remodeling.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.