Abstract

The aim of this study was to assess whether postoperative cardiac troponin T levels could predict ventilation requirements in infants undergoing the arterial switch operation. Cardiac troponin T was measured 6 hours after aortic cross clamping and prior to tracheal extubation in 20 consecutive patients; 10 had simple and 10 had complex (with ventricular septal defect) transposition of the great arteries. The mean plasma troponin T level prior to extubation did not differ significantly in patients who were re-intubated and those who were successfully extubated. The initial cardiac troponin T levels in the complex defect group was significantly higher than in the simple transposition group. There was no correlation between initial cardiac troponin T levels and the duration of mechanical ventilation. There was no difference in mean duration of ventilation between the 2 groups. It was concluded that the postoperative cardiac troponin T level is not a predictor of successful extubation or prolonged artificial ventilation in this subset.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.