Abstract

A new arterial prosthesis made of polytetrafluoroethylene (OTFE) was evaluated in 10 infants with complex cyanotic congenital heart disease. All grafts used were 4 mm. in diameter and varied in length from 0.8 to 6 cm. The grafts were anastomosed to the main pulmonary artery or its bifurcation in 8 infants and to the right and left pulmonary arteries in one each. There were two early deaths, one of which was related to shunt failure. The advantages of a shunt to the main pulmonary artery are obvious, and the intraoperative procedure is facilitated with the prosthesis. Follow-up averages 9 months in the 8 survivors, and the patients have nearly doubled their preoperative weight. A shunt murmur is present in each case and the children have mild-to-moderate cyanosis at rest. Repeat aortograms in 2 patients, 8 and 10 months postoperatively, show a smooth graft without luminal narrowing. The aortic oxygen saturations were 73 per cent. The PTFE graft and/or anastomoses will not grow with the growth of the child and therefore may not accommodate growth by increased flow. This may prove to be a limiting factor in its long-term use in fants. We reserve the use of these grafts for infants with complex cyanotic defects undergoing emergency surgery or in older children in whom a conventional shunt is not possible or a previous shunt has failed.