Abstract

ObjectivePulse (PPV) and systolic pressure variation (SPV) quantify variations in arterial pressure related to heart-lung interactions and have been introduced as biomarkers of preload dependency to guide fluid treatment in mechanically ventilated patients. However, respiratory intra-thoracic pressure changes during spontaneous breathing are considered too small to affect preload and stroke volume sufficiently for the detection by PPV and/or SPV. This study addressed the effects of paced breathing and/or an external respiratory resistance on PPV and SPV in detecting preload dependency in spontaneously breathing subjects.MethodsIn 10 healthy subjects, hemodynamic and respiratory parameters were evaluated during progressive central hypovolemia (head-up tilt). Breathing conditions were varied by manipulating breathing frequency and respiratory resistance. Subjects responding with a reduction in stroke volume index ≥15% were classified as having developed preload dependency. The ability for PPV and SPV to predict preload dependency was expressed by the area under the ROC curve (AUC).ResultsA breathing frequency at 6/min increased the PPV (16±5% vs. 10±3%, p<0.001) and SPV (9±3% vs. 5±2%, p<0.001) which was further enhanced by an expiratory resistance (PPV: 19±3%, p = 0.025 and SPV: 10±2%, p = 0.047). These respiratory modifications, compared to free breathing, enhanced the predictive value of PPV with higher accuracy (AUC: 0.92 vs. 0.46).ConclusionUnder conditions of progressive central hypovolemia, the application of an external respiratory resistance at a breathing frequency of 6/min enhanced PPV and SPV and is worth further study for detection of preload dependency from arterial pressure variations in non-ventilated subjects.

Highlights

  • In anesthesiology and intensive care medicine, fluid administration is the cornerstone of treatment for hypovolemia but the detection of a clinically relevant blood volume deficit remains difficult [1, 2]

  • 40–70% of critically ill patients respond to fluid administration with a clinically significant increase in stroke volume (SV) and cardiac output (CO) [3]

  • The substantial number of patients not responding to fluid therapy calls for physiological markers capable to predict preload dependency or fluid responsiveness—that is, responding to fluid administration by increasing SV [4, 5]

Read more

Summary

Objective

Pulse (PPV) and systolic pressure variation (SPV) quantify variations in arterial pressure related to heart-lung interactions and have been introduced as biomarkers of preload dependency to guide fluid treatment in mechanically ventilated patients. Respiratory intrathoracic pressure changes during spontaneous breathing are considered too small to affect preload and stroke volume sufficiently for the detection by PPV and/or SPV. This study addressed the effects of paced breathing and/or an external respiratory resistance on PPV and SPV in detecting preload dependency in spontaneously breathing subjects. Data Availability Statement: All relevant data are within the paper

Methods
Results
Conclusion
Introduction
Discussion
Limitations
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call