Abstract

Airway closure and arterial blood gases were measured in 11 healthy subjects both before and during anaesthesia with artificial ventilation, prior to routine surgery. The functional residual capacity was then increased by positive end-expiratory pressure (PEEP), so that ventilation took place at a lung volume where no airway closure was present, and the effect on arterial oxygenation was again investigated. A significant increase in alveolar-arterial oxygen gradient occurred in the group of seven patients in whom airway closure within a tidal breath could be demonstrated during anaesthesia, but there was no significant change in the four patients in whom airway closure could not be demonstrated. There was no improvement in arterial oxygenation on increasing functional residual capacity (FRC) in either group. It may well be that this failure to improve oxygenation was due to a deleterious effect of PEEP on the circulation, even though the PEEP was the minimum required to abolish airway closure.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.