SUMMARY The effects of IPPV with a pressure preset ventilator on alveolar-arterial oxygen tension difference, arterial oxygen tension and physiological deadspace were studied in eleven patients undergoing surgery for peripheral vascular disease. No significant difference in these values was found over a period of 2½ hours, but in five of the eleven patients studied, the VD/VT ratio rose by more than 4.7 per cent during the period of study. Possible reasons for this, and for the large increase in A-a Po2 found after induction of anaesthesia, are discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.