We investigated arsenic removal from groundwater by electrocoagulation (EC) using aluminum as the sacrificial anode in a pre-pilot-scale continuous filter press reactor. The groundwater was collected at a depth of 320m in the Bajío region in central Mexico (arsenic 50μgL–1, carbonates 40mgL–1, hardness 80mgL–1, pH 7.5 and conductivity 150μScm–1). The influence of current density, mean linear flow and hypochlorite addition on the As removal efficiency was analyzed. Poor removal of total arsenic (<60%) in the absence of hypochlorite is due to a mixture of arsenite (HAsO2(aq) and H3AsO3(aq)) and arsenate (HAsO42−). Arsenic removal is more efficient when arsenite is oxidized to arsenate by addition of hypochlorite at a concentration typically used for disinfection (1mgL–1). Arsenate removal by EC might involve adsorption on aluminum hydroxides generated in the process. Complete arsenate removal by EC was satisfactory at a current density of 5mAcm–2 and mean linear flow of 0.91cms–1, with electrolytic energy consumption of 3.9kWhm3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.