Abstract

The arrest function in fatigue crack propagation at 25∼550°C in air was investigated, using SUS 304 (18 Cr-8 Ni) and SUS 403 (12 Cr) stainless steels containing 0.2 weight percent dispersed lead particles. The Pmax-constant ΔK-decreasing test, where the minimum load, Pmin, increased with increasing crack length while the maximum load, Pmax, remained constant, was employed in order to avoid crack closure. The main conclusions obtained are as follows : (1) Fatigue crack propagation properties including the threshold were independent of the material at room temperature under the closure-free condition. Fatigue threshold values at temperatures higher than the load melting point of 327°C were about 40% higher for lead-particle-dispersed steels than for host steels. (2) The increase in threshold level at elevated temperatures was explained, considering that the oxide layer spalled at the fatigue crack tip was repaired by the molten lead. Accordingly, we concluded that dispersed lead particles could show the arrest function of the fatigue crack propagation at elevated temperatures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.