Abstract

As the resolution of 3D printing techniques improves, the possibility of individualized, 3-ossicle constructions adds a new dimension to middle ear prostheses. In order to optimize these designs, it is essential to understand how the ossicles and ligaments work together to transmit sound, and thus how ligaments should be replicated in a middle ear reconstruction. The middle ear ligaments are thought to play a significant role in maintaining the position of the ossicles and constraining axis of rotation. Paradoxically, investigations of the role of ligaments to date have shown very little impact on middle ear sound transmission. We explored the role of the two attachments in the gerbil middle ear analogous to human ligaments, the posterior incudal ligament and the anterior mallear process, severing both attachments and measuring change in hearing sensitivity. The impact of severing the attachments on the position of the ossicular chain was visualized using synchrotron microtomography imaging of the middle ear. In contrast to previous studies, a threshold change on the order of 20 dB across a wide range of frequencies was found when both ligaments were severed. Concomitantly, a shift in position of the ossicles was observed from the x-ray imaging and 3D renderings of the ossicular chain. These findings contrast with previous studies, demonstrating that these ligaments play a significant role in the transmission of sound through the middle ear. It appears that both mallear and incudal ligaments must be severed in order to impair sound transmission. The results of this study have significance for middle ear reconstructive surgery and the design of 3D-printed three-ossicle biocompatible prostheses.

Highlights

  • As 3D printing techniques improve in ability to print biocompatible materials at a high resolution, the possibility of designing a three-ossicle middle ear prosthesis individualized to the ear of a patient becomes more achievable [1,2]

  • This paper examines the impact of severing the anterior mallear process and the posterior incudal ligament of the gerbil middle ear on sound transmission and ossicular chain position

  • Between 500–32,000 Hz, compound action potentials (CAPs) threshold differences relative to baseline are -1 dB ± 16 dB with only the anterior mallear process severed (Panel A) and 5dB ± 16 dB with only the posterior incudal ligament severed (Panel B)

Read more

Summary

Introduction

As 3D printing techniques improve in ability to print biocompatible materials at a high resolution, the possibility of designing a three-ossicle middle ear prosthesis individualized to the ear of a patient becomes more achievable [1,2].

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have