Abstract Background Increased concentrations of nickel ions may be released into saliva from recycled NiTi archwires. Aim To compare the nickel ion concentrations released from recycled NiTi wires after sterilisation by either dry heat or steam autoclave. Methods Eighty preformed NiTi wires were assigned to four equal groups. In Groups 1, 2 and 3 the archwires were used intra-orally for 4 weeks. The Group 4 archwires were not used. Group 1 archwires were sterilised by dry heat, the Group 2 archwires were sterilised by steam autoclave, the Group 3 archwires were not sterilised and the Group 4 archwires were as-received. A 2 cm length, cut from each archwire, was immersed in artificial saliva for 4 weeks and the nickel ion concentrations in the artificial saliva measured with an atomic absorption spectrophotometer. Results There were no significant differences in the nickel ion concentrations released into the artificial saliva by each group of archwires (p = 0.467). Conclusion Sterilisation of used NiTi wires by either dry heat and steam autoclave does not affect the concentrations of nickel ions released into artificial saliva.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.