Abstract

National Institute for Occupational Safety and Health researchers are studying the potential for Li-ion-battery thermal runaway from an internal short circuit in equipment approved as permissible for use in underground coal mines. Researchers used a plastic wedge to induce internal short circuits for thermal runaway susceptibility evaluation purposes, which proved to be a more severe test than the flat plate method for selected Li-ion cells. Researchers conducted cell crush tests within a 20-L chamber filled with 6.5% CH4-air to simulate the mining hazard. Results indicate that LG Chem ICR18650S2 LiCoO2 cells pose a CH4 explosion hazard from a cell internal short circuit. Under specified test conditions, A123 Systems 26650 LiFePO4 cells were safer than the LG Chem ICR18650S2 LiCoO2 cells at a conservative statistical significance level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.