Abstract

The routine use of stems in revision TKA improves survival rates by enhancing the stability of the prosthesis. The ideal method of stem fixation (cemented or uncemented) in two-stage reimplantation remains controversial. The purpose of this study was to answer the following questions: (1) Are rerevision rates for aseptic loosening comparable between cemented stems and uncemented stems in two-stage reimplantation? (2) Is the reinfection rate comparable between antibiotic-impregnated cemented stems and uncemented stems for two-stage reimplantation? (3) Are there any differences in Knee Society radiographic scores between stem techniques? A retrospective analysis was performed in all patients who underwent two-stage reimplantation between 1990 and 2010 at Anderson Orthopaedic Research Institute (AORI) and OrthoCarolina (OC). One hundred fourteen patients with 228 stems met the inclusion criteria. Of these 228 stems, 102 stems were cemented and 126 stems were uncemented. The indication for stem fixation was largely institution specific; AORI used cementless stems 92% (118) of the time, whereas OC used a cemented stem 92% (92) of the time. A 2-year minimum radiographic and clinical followup was required for inclusion into the study. Radiographic evaluations were performed using a modification of the Knee Society radiographic score. Rerevision rates for aseptic loosening were comparable with three cemented and three cementless stem constructs. The reinfection rate was also comparable between cemented and cementless stems (p = 0.86). Using post hoc analysis, 32% of cemented stems were radiographically classified as loose or closely observe (33 of 102) compared with 17% of the cementless stem group (21 of 126; p = 0.006). Patients with good bone quality had a significantly lower rate of radiographic loosening compared with patients with poor bone quality (p = 0.01). There was no significant correlation with radiographic loosening and level of constraint (p = 0.90) or use of articulating versus static antibiotic spacer (p = 0.06). In this retrospective study, cementless diaphyseal-engaging stems had a lower rate of radiographic failure than did cemented stems in two-stage reimplantation. Reinfection rates remain similar despite the absence of antibiotic cement in the cementless constructs. At this time we believe the use of hybrid, cementless diaphyseal-engaging stems should be considered as a possible option at the time of reimplantation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.