Abstract

Flow property measurements that were recently acquired in the Ames Research Center Aerodynamic Heating Facility arcjet using two-photon laser-induced fluorescence (LIF) of atomic nitrogen (N) are reported. The flow properties, which include velocity, translational temperature, and N concentration, were measured simultaneously over a range of facility operating conditions for N(2)-argon test gas flows in the 30-cm-diameter nozzle. A recent measurement of the two-photon excitation cross section for the 3p(4)D degrees <-- 2p(4)S degrees transition of atomic nitrogen is used to convert the relative nitrogen concentration measurements to absolute values, and a nitrogen flow reactor is used to provide a room-temperature, reference-wavelength calibration of the translational temperature and velocity measurements. When combined with information from facility measurements, an analysis of the flow properties obtained using two-photon LIF of N yields the total free-stream flow enthalpy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.