Abstract

Background Detection of HTLV infection continues to be important to control spread of human retroviruses and to protect safety of blood supply. The ARCHITECT rHTLV-I/II assay is a chemiluminescence-based immunoassay, which utilizes HTLV-I, and HTLV-II recombinant antigens and peptides in a double-antigen-sandwich assay format on the Abbott ARCHITECT automated platform. Precision, sensitivity and specificity of the ARCHITECT rHTLV-I/II assay is being presented. Methods Assay performance was evaluated on confirmed HTLVI/II positive specimens and specimens from German Blood Donors and hospitalized patients. External performance evaluation was conducted at two different sites in Portugal. Murex HTLV-I/II EIA was used as comparator assay and INNO-LIA or MP diagnostics HTLV Blot were used for confirmation. Results The ARCHITECT rHTLV-I/II assay detected all HTLVI and HTLV-II specimens (N=406) in accordance to the Murex assay. Analytical sensitivity was equivalent to Murex based on end-point-dilutions. Specificity on HTLV-I/II blood donors was 99.95% (N=5646; 95% CI 99.84-99.99%), SD to cut-off was 15.6. Specificity on a diagnostic population was 99.86% (N= 692; CI 95% 99.20-100%). Precision for samples (1-6 S/CO) was 3.984.31%. Presented data support selected cut-off multiplier-value of 0.25 for the ARCHITECT rHTLV-I/II assay. Results from the Receiver-Operating-Curve showed a 99.98% area under the curve which is indicative of high separation power between negative and positive populations. Conclusions This study demonstrated excellent sensitivity and specificity of the ARCHITECT rHTLV-I/II assay. The assay is suitable for both blood screening and diagnosis of HTLV infections and therefore reduces risk of transfusion transmitted HTLV and improves safety of blood supply.

Highlights

  • Detection of HTLV infection continues to be important to control spread of human retroviruses and to protect safety of blood supply

  • This study demonstrated excellent sensitivity and specificity of the ARCHITECT rHTLV-I/II assay

  • The assay is suitable for both blood screening and diagnosis of HTLV infections and reduces risk of transfusion transmitted HTLV and improves safety of blood supply

Read more

Summary

Background

Detection of HTLV infection continues to be important to control spread of human retroviruses and to protect safety of blood supply. The ARCHITECT rHTLV-I/II assay is a chemiluminescence-based immunoassay, which utilizes HTLV-I, and HTLV-II recombinant antigens and peptides in a double-antigen-sandwich assay format on the Abbott ARCHITECT automated platform. Sensitivity and specificity of the ARCHITECT rHTLV-I/II assay is being presented. Indicative of high separation power between negative and positive populations

Conclusions
Methods
Results
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.