Abstract

AbstractTo disclose the impact of SF6 gaseous medium on Ag/Ti3SiC2 contact materials, arc discharges on the Ag/Ti3SiC2 cathodes were performed 100 times in SF6 gas at 10 kV. After 1, 50, and 100 times of arc discharges, the morphologies of arc‐eroded surfaces were characterized. The changes in breakdown strength with the number of tests were recorded. After 100 times of arc erosion, the composition of the surface was characterized, and the morphologies and compositions of the cross section were measured. In the process of multiple arc breakdowns, the arc erosion position randomly changes. In the later stage of tests, the breakdown strength of Ag/Ti3SiC2 increased. The protrusion on the arc‐eroded surface is the ignition point for the arc, the down of protrusion height and the smooth of protrusion tip were observed after multiple arc discharges, which may result in the increase in breakdown strength. After multiple arc erosion tests, Ag2S was detected on the surface by XPS, and part of silicon elements were dissociated outward from Ti3SiC2. The composition change is inferred to be one of the reasons for the rise of breakdown strength.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.