Abstract

Mercuric ion, inorganic metal ion, found in three oxidation state in nature, including elemental mercury (Hg0), mercurous ion (Hg+), and mercuric ion (Hg2+). These three forms possess hazardous environmental contaminant and are extremely toxic metal materials to damage mammalian organs.[1] This work demonstrates a label-free technique for Hg2+ ions detection using capped gold nanowire arrays based sensors[2] combined with the electrochemical surface plasmon resonance method. The three-electrode electrochemical analysis (Fig. 1) and optical transmission measurement were employed to characterize the potential-current responses and the resonant peak signals were for the investigation of metal ion electrodeposition (Fig. 2). The nanostructured EC-SPR sensors were used to characterize the eletrochemical behaviors of K3Fe(CN)6/K2Fe(CN)6 redox couple and evaluate the wavelength sensitivity (480.3 nm RIU-1) with a FOM of 40.0 RIU-1 and the intensity sensitivity (1819.9 %) in the glycerol-water solutions. Fig. shows the detection limit of 1 pM Hg2+ can be obtained by the chronoamperomet- ric-spectrum analysis. The developed capped gold nanowire arrays based sensors present Hg2+ ion selectivity over the wavelength shifts of the interfering ions including Ca2+, Co2+, Ni2+, Na+, Cu2+, Pb2+, and Mn2+ ions. The developed capped gold nanoslit arrays based sensors present Hg2+ ion selectivity over the wavelength shifts of the interfering ions including Ca2+, Co2+, Ni2+, Na+, Cu2+, Pb2+, and Mn2+ ions. The proposed flexible capped gold nanowire arrays based sensor is applicable to be an EC-SPR label-free platform and enabled a rapid, sensitive and selective sensing method for aqueous Hg2+ detection. The application of biomolecule analysis can be further evaluation in the future. applicable to be an EC-SPR label-free platform and enabled a rapid, sensitive and selective sensing method for aqueous Hg2+ detection. The application of biomolecule analysis can be further evaluation in the future. Fig.1.Schematic representation of electrochemical surface plasmon resonance configuration set-up for mercury ions detection. Fig. 2 Redox current curves during the first cyclic voltammetry scan and the simultaneously measured surface plasmon resonance intensity. Fig. 3. The wavelength shifts and the intensity changes of gold nanowire arrays against Hg2+concentrations between 100|rM and 100nM. The inset shows the reduction reaction currents of amperometric responses at various Hg2+ concentrations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call