Abstract

In this study, we developed a simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to quantify trastuzumab in human serum using aptamers for sample purification. Trastuzumab was extracted from serum samples using the capture probe based on its aptamer CH1S-3, followed by reduction, alkylation, trypsin digestion, and quantification using LC-MS/MS. Additionally, a unique peptide, FTISADTSK, was employed as a surrogate peptide and quantified, and *FTISADTSK (13C915N-labeled phenylalanine) was used as an internal standard to minimize variability in detection among the samples. The detection range for this method was 0.5–250 μg/mL, with a high correlation coefficient (r2 > 0.99). The intra- and inter-day precision (%CV, the coefficient of variation) of the quality control samples was less than 12.7%, and the accuracy (%bias) was below 8.64%. After optimization and verification, this assay was used to determine trastuzumab levels in clinical human serum samples. The results indicated that the trastuzumab concentrations had an approximate 4-fold difference among ten patients (range: 11.80–41.90 μg/mL). This study provides a novel approach for the accurate and quantitative monitoring of the mAb—trastuzumab.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call