Abstract

0167-8140/$ see front matter 2008 Elsevier Irelan doi:10.1016/j.radonc.2008.09.002 * Corresponding author. Address: Department of Bio University Hospital, Brendstrupgaardsvej, DK-8200 A E-mail address: sha@mta.aaa.dk (S. Haack). Background and purpose: To elaborate a method for applicator reconstruction for MRI-based brachytherapy for cervical cancer. Materials and methods: Custom-made plastic catheters with a copper sulphate solution were made for insertion in the source channels of MR-CT compatible applicators: plastic and titanium tandem ring applicators, and titanium needles. The applicators were CT and MR scanned in a phantom for accurate 3D assessment of applicator visibility and geometry. A reconstruction method was developed and evaluated in 19 patient MR examinations with ring applicator (plastic: 14, titanium: 5). MR applicator reconstruction uncertainties related to inter-observer variation were evaluated. Results: The catheters were visible in the plastic applicator on T1-weighted images in phantom and in 14/ 14 clinical applications. On T2-weighted images, the catheters appeared weaker but still visible in phantom and in 13/14 MR clinical applications. In the titanium applicator, the catheters could not be separated from the artifacts from the applicator itself. However, these artifacts could be used to localize both titanium ring applicator (5/5 clinical applications) and needles (6/6 clinical applications). Standard deviations of inter-observer differences were below 2 mm in all directions. Conclusion: 3D applicator reconstruction based on MR imaging could be performed for plastic and titanium applicators. Plastic applicators proved well to be suited for MRI-based reconstruction. For improved practicability of titanium applicator reconstruction, development of MR applicator markers is essential. Reconstruction of titanium applicator and needles at 1.5 T MR requires geometric evaluations in phantoms before using the applicator in patients. 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 91 (2009) 187–193

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.