Abstract

Objective: To establish a method for determination the S-phenylmercapturic acid in urine by dispersive solid-phase extraction using Humic Acid/Fe(3)O(4) magnetic nanocomposite as adsorbent. Methods: The 5 ml of urine samples were adjusted to pH 1.0 and extracted by Fe3O4@HA. Then the analytes were separated on EC-C(18) capillary column and detected by HPLC-VWD. The S-phenylmercapturic acid was characterized by the retention time and quantified by peak area and external standard method. Results: The standard curves of SPMA showed significant linearity between 0.04~1.00 mg/L (r=0.999 7) . The average recovery was 94.2%~102.4%. The intra-day and inter-day precisions (RSD) were 2.9~6.7% (n=6) and 3.1~7.5% (n=6) respectively. The detect limit of SPMA was 0.012 g/L (S/N=3) . Conclusion: This method is simple, rapid, sensitive and accurate. It is applicable for determination of SPMA in the urine of works who were exposed to benzene.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.