Abstract

Internal mammary vessels (IMVs) are widely used recipient vessels in abdominal free flap breast reconstructions. Rib sparing technique is an alternative method with less damage in IMVs exposure. This study aims to investigate the factors influencing the selection of IMVs, as well as analyze the applicability and related factors of rib sparing technique in abdominal breast reconstruction. Medical records of 215 patients who underwent abdominal free flap reconstruction from November 2006 to December 2017 in Fudan University Shanghai Cancer Center (FUSCC) were analyzed. Intercostal space (ICS) was measured from preoperative chest computed tomography scan. Factors influencing the choice of recipient vessels and rib sparing were analyzed. Surgery time, hospitalization and complications were assessed. Among all 218 flaps, 172 flaps used IMVs as the recipient vessels while 46 used other vessels. patients with immediate reconstruction (P=0.005) and axillary lymph nodes dissection (ALND) (P<0.001) were less likely to use IMVs. Patients' body mass index (BMI) and radiotherapy history showed no statistically significant differences between the two groups (P=0.338 and 0.811). In IMVs group, 62% cases used rib sparing technique. Compared with rib resection group, patients with rib sparing were taller (P=0.047) and with a wider ICS (2.65±0.54 vs. 2.25±0.38 cm, P<0.001). Rib sparing group had a shorter surgery and postoperative hospitalization time, as well as a lower complication rate, but the differences were not statistically significant (P=0.120, 0.450 and 0.612). IMVs were used more frequently as the recipient vessels in abdominal free flap breast reconstructions, especially when axillary operation was not performed at the same time. Rib sparing technique had the potential to decrease surgery time, hospitalization days and complications rate. It could be applied in most of the patients with IMVs exposure, particularly in taller patients and patients with a wider ICS. Preoperative chest computed tomography scan can be used to assess the ICS width to provide operational suggestions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.