Abstract

In order to solve the shortcomings of traditional methods of concrete curing in winter, proposed self-regulating heating cable new concrete curing methods. Several aspects were considered, about the heating cable length and heating time, heating temperature. According to energy conservation, heating and heat dissipation balance, derived formulas of heating cable normal use length and minimum. As conclusions is shown, first, the normal length design can controlled better heating temperature, it use the cable length and heating time, heating temperature two parameters to control the other parameters. Second, it is better heating efficiency, can be the overall warming state quickly. In addition, when the concrete pouring temperature is above 10 °C, it is not need additional heating, and it can choose minimum length design formula.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.