Abstract

The X-ray absorption fine structure method was applied for the quantitative analysis of hexavalent Cr in electronic products. The pre-edge peak intensity of the Cr K-edge increased according to the hexavalent Cr amount, and the hexavalent Cr ratio was calculated quantitatively by using the intensity. By combining with inductively coupled plasma atomic emission spectroscopy measurement results that gave the total Cr amount, the absolute amount of hexavalent Cr in chromate conversion coating and plastic samples could be evaluated. The results obtained by this method were in good agreement with those obtained by the chemical analysis method. This method can be successfully applied for the determination of hexavalent Cr amount in electronic products such as chromate conversion coating and plastic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.