Abstract
This paper presents a methodology for glaucoma detection based on measuring displacements of blood vessels within the optic disc (vascular bundle) in human retinal images. The method consists of segmenting the region of the vascular bundle in an optic disc to set a reference point in the temporal side of the cup, determining the position of the centroids of the superior, inferior, and nasal vascular bundle segmented zones located within the segmented region, and calculating the displacement from normal position using the chessboard distance metric. The method was successful in 62 images out of 67, achieving 93.02% sensitivity, 91.66% specificity, and 91.34% global accuracy in pre-diagnosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.