Abstract

With the development of automatic control in the HVAC industry, more and more buildings have adopted automatic control of air conditioning, HVAC systems, but most of the control results can not be satisfactory. The research object of this paper is the elevator machine room equipped HVAC, through accurate control of that room temperature can greatly reduce the elevator shutdown caused by the action of the temperature protection circuit, so as to improve the safety of elevator operation. This paper gives three different temperature control methods, establishes the math representation of the temperature system in the machine room, specifically designs the classical PID controllers, Fuzzy PID controllers and variable domain Fuzzy PID controller, and simulates and analyzes the three algorithms respectively, The results indicate that in comparing the above three algorithms, the variable domain fuzzy PID algorithm has an adjustment time of 63s, and the overshooting amount of 0.4%, which is the best among the three control algorithms.